An essential component of a building’s passive fireproofing strategy are fire doors. They are employed in the process of fire compartmentation, which involves erecting physical barriers at key locations surrounding a structure to impede the spread of smoke and flames in the case of a fire. In this article, we describe their composition, the level of protection they provide, and the legal requirements for them.
Read More: Fire Door Manufacturers
What material do fire doors consist of?
It is possible to construct fire doors out of steel, aluminum, gypsum, and wood. Additionally, they may feature windows with anti-shatter wire mesh and be composed of ceramic or borosilicate glass, both of which have a stronger fire resistance than regular glass.
Fire doors are flush with the frame to improve their fire-fighting capabilities; any gaps are filled with fire-resistant sealant made of silicone. In order to stop smoke from seeping below, they are sometimes supplemented by an intumescent strip fastened at the base of the door. This strip swells when exposed to heat.
Closing mechanisms are frequently incorporated into the construction of fire doors. These spring-loaded or hydraulic devices, which are often installed at the top of doors, push doors shut to stop smoke and fire from spreading from one place to another.
Although many doors may have some or all of these characteristics, it’s important to remember that they are not always “fire doors.” A manufacturer’s certification is required for a design to be referred to be a “fire door.” After a door passes many tests at an authorized facility, such as a fire and stress simulation, it is certified as a fire door. A sticker with the manufacturer, year of production, and determined fire rating placed to the top edge of the door indicates which doors have received certification.
For what length of time does a fire door shield you?
Fire doors come in many classes, and each one offers a distinct degree of security. Depending on how long they can resist fire, the grades are divided. FD30 (30 minutes), FD60 (60 minutes), FD90 (90 minutes), and FD120 (120 minutes) are the primary ones.
The “certified core thickness” of the doors is the primary factor that separates the classes. This is the door’s primary material, which is frequently covered in an aesthetically pleasing covering of a different substance.
Offices and residential buildings often employ FD30 and FD60 internally. For the protection of important facilities or highly valued properties, any rating higher than FD60 is more typical.
When are fire exits necessary?
The following incorporations and Fire Safety: Approved Document B cover all rules concerning the usage of fire doors. The law states that all doors leading from a livable room (not a restroom, for example) to a stairway (at every level) must be fire doors in residential structures taller than two stories. The criteria for fire doors in commercial and non-domestic buildings differ depending on whether the escape routes are horizontal or vertical.
Rating for fire doors
The length of time (measured in hours or minutes) that fire doors are supposed to offer protection is indicated on their labels. The type of door—one leaf representing one door, two leaves representing two doors—is also given in addition to the time. The building’s size, purpose, and complexity all play a role in choosing the right fire door. Fire doors may not be essential in situations when a safe exit is obvious; nevertheless, in complicated buildings or situations where people might need aid to escape, fire doors with greater fire ratings could be required.